Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Method Method Duration Post Insult Type Post Insult Time Value Post Insult Time Unit Record ID Study ID
SD left ventricular end-systolic blood pressure sham surgical control condition (for 6 hours) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) (for 0 hours) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 58.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 sham ACF 360 min 98831 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 12 hours) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 62.0 mmHg 2.0 4.9 vascular transducer tipped catheter 1.0 sham ACF 720 min 98833 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 28 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 98 days 7 85.0 mmHg 3.0 7.94 vascular transducer tipped catheter 0.0 sham ACF 28 days 99319 2278
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 28 days) then Aprotinin (12000 kIU) (for 28 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 98 days 8 70.0 mmHg 3.0 8.49 vascular transducer tipped catheter 0.0 ACF 28 days 99322 2278
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 56.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 ACF 2 days 98834 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 2 days) then Aprotinin (12000 kIU) (for 2 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 72 days 5 58.0 mmHg 2.0 4.47 vascular transducer tipped catheter 0.0 sham ACF 2 days 99317 2278
SD left ventricular end-systolic blood pressure sham surgical control condition (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 66.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 sham ACF 2 days 98835 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 2 days) then metoprolol (100 mg/kg/d) (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 64.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 sham ACF 2 days 98841 2160
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 2 days) then Aprotinin (12000 kIU) (for 2 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 72 days 5 57.0 mmHg 4.0 8.94 vascular transducer tipped catheter 0.0 ACF 2 days 99318 2278
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 12 hours) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 61.0 mmHg 2.0 4.9 vascular transducer tipped catheter 1.0 ACF 720 min 98832 2160
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 2 days) then vehicle control condition (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) (for 0 hours) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 56.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 ACF 2 days 98838 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 2 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 72 days 5 55.0 mmHg 3.0 6.71 vascular transducer tipped catheter 0.0 sham ACF 2 days 99315 2278
SD left ventricular end-systolic blood pressure sham surgical control condition (between 120 and 12 hours) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) (for 0 hours) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 58.0 mmHg 2.0 4.9 vascular transducer tipped catheter 1.0 sham ACF 5 days 98837 2160
SD left ventricular end-systolic blood pressure sham surgical control condition (for 28 days) then Aprotinin (12000 kIU) (for 28 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 98 days 7 86.0 mmHg 5.0 13.23 vascular transducer tipped catheter 0.0 sham ACF 28 days 99321 2278
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 5 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 71.0 mmHg 5.0 12.25 vascular transducer tipped catheter 1.0 ACF 5 days 98836 2160
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 28 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 98 days 8 75.0 mmHg 2.0 5.66 vascular transducer tipped catheter 0.0 ACF 28 days 99320 2278
SD left ventricular end-systolic blood pressure sham surgical control condition (for 2 days) then vehicle control condition (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 64.0 mmHg 3.0 7.35 vascular transducer tipped catheter 1.0 sham ACF 2 days 98839 2160
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 2 days) Wei CC, et al., PLoS One. 2012;7(6):e40110. doi: 10.1371/journal.pone.0040110. Epub 2012 Jun 29. heart left ventricular blood pressure trait male 72 days 5 61.0 mmHg 3.0 6.71 vascular transducer tipped catheter 0.0 ACF 2 days 99316 2278
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 6 hours) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 72.0 mmHg 4.0 9.8 vascular transducer tipped catheter 1.0 ACF 360 min 98830 2160
SD left ventricular end-systolic blood pressure artificial aortocaval fistula (for 2 days) then metoprolol (100 mg/kg/d) (for 2 days) then ketamine (80 mg/kg) (for 0 hours) and xylazine (10 mg/kg) (for 0 hours) Seqqat R, et al., J Mol Cell Cardiol. 2012 Aug;53(2):240-9. doi: 10.1016/j.yjmcc.2012.05.004. Epub 2012 May 15. heart left ventricular blood pressure trait male 0 days 6 57.0 mmHg 2.0 4.9 vascular transducer tipped catheter 1.0 ACF 2 days 98840 2160