Phenominer Database Results (8 results)

 

Table "column sort" updates the order of the bars in the chart.
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Individual Records Method Method Duration Post Insult Time Value Experiment Notes Record ID Study ID
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 7 96.91 mmHg 8.11 21.45 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 44875 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 3 106.11 mmHg 2.59 4.49 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45563 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 9 103.69 mmHg 4.45 13.34 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 44874 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 2 127.8 mmHg 11.1 15.7 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45564 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 5 137.08 mmHg 8.45 18.89 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45787 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 9 132.24 mmHg 4.63 13.88 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45788 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 8 96.53 mmHg 6.97 19.7 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 49946 461
FHH-Chr 13BN/Mcwi left ventricular systolic blood pressure controlled air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 10 102.76 mmHg 5.63 17.79 Download Values balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 49947 461