Phenominer Database Results (8 results)

 

Table "column sort" updates the order of the bars in the chart.
Strain Phenotype Conditions Study Experiment Name Sex Age # of Animals Value Units SEM SD Individual Records Method Method Duration Post Insult Time Value Experiment Notes Record ID Study ID
FHH-Chr 4BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 8 69.71 mmHg 4.04 11.44 balloon tipped catheter with pressure transducer in isolated perfused heart 0 46768 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 9 35.33 mmHg 3.82 11.46 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47929 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 6 34.45 mmHg 5.96 14.6 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45286 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 8 32.7 mmHg 4.05 11.46 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 47927 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) then perfusate suspended (for 0.4 hours) then controlled oxygen content Kreb's solution perfusate (for 0.7 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 9 27.33 mmHg 3.79 11.38 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 45288 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 8 75.32 mmHg 5.46 15.44 balloon tipped catheter with pressure transducer in isolated perfused heart 0 46766 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait male 49 days-63 days 8 99.35 mmHg 7.39 20.91 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 48640 461
FHH-Chr 4BN/Mcwi left ventricular developed pressure air oxygen content (12 %) (for 14 days) then controlled oxygen content Kreb's solution perfusate (for 0.5 hours) PhysGen Cardiac data heart left ventricular blood pressure trait female 49 days-63 days 9 100.14 mmHg 8.24 24.72 balloon tipped catheter with pressure transducer in isolated perfused heart 0 Moms and pups used in studies were fed Teklad 48642 461